Refill the nitrogen every day regardless of IRIS working or not.

Cheatsheet

  1. Fill the camera dewar with liquid nitrogen (LN2).
  2. Open the VNC connections to the IRIS computers - use Remmina

    1. 192.168.7.130 (irisp)
    2. 192.168.7.133:1 (irisc:1)
    3. 192.168.7.133:2 (irisc:2)
  3. When Sun at +1°, on irisc (in one of the Xterms):

    iris_dome.py -open
    

  4. On irisp: Pilar → ON (activate the telescope)
  5. On irisc:
    ssh irisuser@irisccd
    iriscom
    
    acsRunup
    irisCCDGUI
    
    1. Select the camera (iris)
    2. Connect
    3. Camera ON
  6. On irisc:
    cd ~/cwest/
    
    When Sun at -4°
    ./irisSkyFlats.py K 5 H 5 J 5
    
    When Sun at -16°
    ./irisPlan_dome.py <obs_plan_file>
    
    Optionally:
    display lastfocus.png (optional)
    
    At the end of the night when Sun at -18°
    killPlan
    
    When Sun at -7°
    ./irisSkyFlats.py J 5 H 5 K 5
    
  7. On irisc: Disconnect → Quit (in the IrisCCDGUI window)
    acsStop
    killACS
    
  8. On irisp: Pilar → OFF
  9. On irisc:
    iris_dome.py -park
    iris_dome.py -close
    
Context Action Console
Prepare the observing plan for the night WHITE
4-6 p.m. Fill the camera dewar with liquid nitrogen (LN2). WHITE
zenith Remmina → select:
irisp password ****
irisc password *****
WHITE
irisc > iris_dome.py -open (SUN_ALT 1°) WHITE
irisp Pilar → ON (activate the telescope, wait) WHITE
irisc
irisccd
> ssh irisuser@irisccd password irisuser
> iriscom (start the communication with the camera)
YELLOW
irisc > acsRunup (wait ~1 min., check if 6 terminals have Ready) ORANGE
irisc > irisCCDGUI → Choose camera → IRIS → Connect → Camera on GREEN
irisc > cd ~/cwest/
> ./irisSkyFlats.py K 5 H 5 J 5 (SUN_ALT -3°)
BLUE
irisc > ./irisPlan_dome.py <plan_file> (SUN_ALT -16°)
> display lastfocus.png
BLUE
irisc observations... BLUE
irisc irisPlan → Ctrl+C / Ctrl+Z
> killPlan (SUN_ALT -18°)
BLUE
irisc > ./irisSkyFlats.py J 5 H 5 K 5 (SUN_ALT -7°) BLUE
irisc IrisCCDGUI → Camera off → Disconnect → QUIT
ds9 → exit
WHITE
irisc > acsStop (wait)
> killACS (wait)
WHITE
irisccd > quit
> exit
YELLOW
irisp Pilar → OFF (wait) WHITE
irisc > iris_dome.py -park WHITE
irisc > iris_dome.py -close WHITE

Description

With IRIS we can observe stars in range K = 8-14 mag and up to K = 3 mag with the neutral density filter (ND99).

IRIS observes in the dithering mode. By default we take 11 subframes in each filter, with slightly different pointings, randomly chosen within a box of a size 30-60'' (depending on the setup, which we will have ability to adjust in the future). The ditherred observations in one filter take about 7 min; there's no possibility of changing the exposure time for now. The camera takes short (about 2s) and long (about 14s) exposures simulanously, and the "short" exposure ends earlier, while the "long" exposure still lasts.

The exposure time saved in the header is not the same as the real exposure time!

For the "short" exposure the real texp = 2.28s (always) and for the "long" exposure the real texp = t + (2 ⨉ 2.28). E.g. if the exposure time from the header is t = 10s, then the real "long" texp = 14.56s and "short" texp = 2.28s. Together with overheads the estimated time needed for one filter (given the exposure time in the header of 10s) is about 7 minutes.

In order to observe brighter stars without the blocking filter, one can defocus the telescope a little (we don't know how to defocus yet). Keep in mind that this strategy should be followed by aperture photometry only, as profile photometry will fail because the profiles of stars won't be gaussian anymore.

We do not observe standard stars with IRIS because we standardize the photometry to 2MASS.

Contact person

In case of any problems not covered by Troubleshooting Piotr Wielgórski
pwielgor@camk.edu.pl, pwielgorski@gmail.com
WhatsApp +48 518 385 197

Liquid nitrogen (LN2)

Refilling (around 5 p.m.)

The IRIS camera has to be kept at the temperature of liquid nitrogen (LN2, 77K) to minimise thermal noise, and a vaccum is needed to minimize the loss of cold. The camera has to be cooled down with LN2 daily. In order to cool the camera down you need to fill the camera's dewar with LN2. Time intervals between consecutive fillings must be shorter than 26 hours, otherwise LN2 will evaporate from the dewar completely, IRIS camera will start to warm up, and the vacuum will be lost (restoring takes 2 days). For that reason, refill the camera even if you won't observe, even if the telescope is partially shut down due to low energy reserves at OCM, unless specifically instructed by Piotr Wielgórski – this way the camera stays cool and prepared for when the weather gets better. There's an alarm in OCA-phone set to 5 p.m. every day to remind you about refilling IRIS with LN2.

The LN2 tank is located on the ground floor in the IRIS dome (see Fig. 1.) The metal hose goes from the tank to the upper floor. When not used, the metal hose should be attached to the wall (Fig. 2).

Location of the liquid nitrogen dewar in the IRIS dome
Fig. 1. Location of the liquid nitrogen tank in the IRIS dome.

Metal hose that supplies IRIS with liquid nitrogen
Fig. 2. Metal hose that supplies IRIS camera with liquid nitrogen (LN2). When idle, it should be attached to the wall, as in the photo.

Health hazard

When handling LN2, keep the doors/dome shutter always open for ventilation (or at least slightly open or not fully closed). 1 liter of liquid nitrogen will evaporate to 700 liter of gaseous nitrogen. This can bring down the percentage of oxygen in the air to such a level that can you loose your consciousness very quickly without any warning - you have no sense to detect the loss of oxygen in your enviroment.

The contact with liquid nitrogen can be dangerous and burn your skin, so always wear thick protective gloves to protect your hands and glasses to protect your eyes. Any metall at your body (e.g. rings) have to be taken off because of the conduction of cold. Especially dangerous is the contact over several seconds, e.g. LN2 gets inside your shoes or inside the gloves. In this case remove the gloves/shoes immediately!

Filling IRIS with LN2 requires 2 people. Both of you must always wear gloves.

  1. Enter IRIS dome. Keep the door open if the weather conditions allow (not too cold, not too windy); use the metal hook on the outside of the dome to attach the door and lock it in the open position. One observer finds gloves next to the LN2 tank and puts them on. The other one goes up, opens slightly the dome shutter, finds gloves on top of a fuse box, and puts them on, too.

    Important

    Make sure that IRIS is parked before opening the door to the upper floor. Check it on the CCTV camera. If IRIS is not parked, you can damage the telescope, the cables, or the door itself. Open the doors slowly.

  2. The observer upstairs connects the rubber hose to the metal pipe on a dewar of the IRIS camera, as shown in Fig. 3. The holding elements (clothes pegs and elastic ropes, Fig. 4) keep the metal hose in place and the rubber hose not kinked without the need of holding it with your hands. You can move the dome slightly to get the best angle and pulling strength of the holding elements. If you don't use clothes pegs, the gaseous nitrogen coming from the rubber hose will propel the rubber hose away from the metal pipe; you then must hold it with your hands until the rubber hose freezes and the liquid nitrogen starts to flow.

    connection of the rubber hose to IRIS
    Fig. 3. Connection of the rubber hose to IRIS from 2 different perspectives.

    Holding elements that keep the metoal hose in place
    Fig. 4. Holding elements that keep the metal hose in place.

  3. The observer downstairs, wearing gloves, checks the pressure on the gauge (Fig. 5); the operational pressure should be about 0.5-0.7 bar. If it is higher, use valve 1 to let the gaseous N2 go out, and close it when the pressure is slightly below 0.7 bar. Releasing gaseous nitrogen produces loud hissing noise; it's expected though uncomfortable. If the pressure is too low, use valve 2 until it reaches 0.5-0.7 bar.

    IRIS LN2 tank valves
    Fig. 5. Valves on the LN2 tank. Valve 1: removes LN2 into the ambient, which lowers the pressure; 2: increases pressure; 3: moves LN2 through the metal hose to IRIS; A: a secure release pressure valve, in the case of high pressure it starts to release the pressure with noise; B: a knob that activates the LN2 level indicator when loosened (i.e. turned counter-clockwise by 2 revolutions), tight it back after the reading of LN2 level.

  4. When the pressure in the tank is good, open valve 3, and LN2 will travel inside the metal hose up to IRIS.

  5. Refilling IRIS camera takes between 5-11 minutes, depending on how full the tank is (the fuller the faster it goes). During this time, if the pressure in the LN2 tank downstairs rises above 0.7 bar, regulate it with valve 1. IRIS is full when the LN2 starts to drip from the holes around the metal pipe (Fig. 6.) Once the observer upstars notices it, (s)he immediately notifies the observer downstairs to close the valve 3 on the tank (gently as it is frozen).

    liquid nitrogen overflow
    Fig. 6. Liquid nitrogen driping out of the camera dewar.

  6. The observer from downstairs joins the observer upstairs and starts to warm up the rubber hose with a heating gun (lying on the ground in the upper floor) to defrost it. In the meantime the other observer removes the holding elements, and holds the metal hose in their hands (protected with gloves!) for a few minutes, until the rubber hose warms up enough to be disattached from the metal pipe. The gun works poorly, so you have to keep it really close to the rubber hose. Once the rubber hose is loose, remove it slowly and attach the metal hose back to the wall.

    heating gun
    Fig. 7. Warming up the rubber hose with a heating gun. The gun works poorly, so you have to keep it really close to the hose.

  7. Before finishing, make sure that all the items in the dome are removed from the telescope's path, so nothing gets destroyed when the telescope moves during observations.

  8. As you go down the stairs and close the platform door, pay attention to the sensors and their wheels as they should slide when the door closes. One sensor doesn't respond properly, it bends instead; hold the sensor as you close the door and place it gently in its proper position on the closed door. If you skip this step, IRIS will raise an error and won't let you observe.

  9. Check the level of LN2 in the tank (Fig. 5, knob B). Turn the knob counter-clockwise by 2 revolutions to activate the LN2 level indicator. Tight it back after the reading.

Leave valve 2 slightly open when the tank is full

When the tank is really full it is recommended to keep valve 2 a bit (a very little bit) open during the night. The next day you will see the drop in pressure to more operational values.

Refill twice per day when humidity above 50%

When the relative humidity in the air is above 50% for longer than [insert time interval, 2h?] prior to the refilling, it is needed to cool the camera down 2 times a day. Otherwise the valves [which valves?] may get blocked by water ice freezing on the camera; if this happens, proceed to IRIS troubleshooting.

Ordering

When an indicator of the LN2 level touches the black medium bar or is below it (Fig. 8), it is time to order a new tank from Paranal. This happens every 17-20 days. Write an email to par-sqa@eso.org from the ocacontrolroom account and request a new tank (copy-paste an earlier message). Usually ESO delivers nitrogen within 1-2 days.

level to order
Fig. 8. The level of LN2 indicating it is time to order a new tank.

On the day of delivery:

  1. You will receive a notification to OCA-phone that an email from "UniFi OS, SUDM" reports on arrivale of a vehicle. That's how you know in a little advance that they guys are coming. Once they arrive they and you don't show up immediately, they will start honking.
  2. Take they IRIS key, open them the IRIS doors, and also the smaller side door (pull hinges up and down), and show the platform that they will use to take out the old tank and put the new one inside. They probably know where the platform is anyway.
  3. They will work for about 10 min, they will remove the metal hose from the tank and replace the empty tank with the full one, and install the same hose.
  4. Once installed, the pressure will be very low, close to zero. No worries, because you will increase it with valve 2 (Fig. 5) to the level 0.5-0.7 as you prepare for your daily refill of IRIS.
  5. Close the side doors, turn off the lights if you turned them on, lock the IRIS door with the key.
  6. Report the delivery in OCM calendar.

Prepare, plot, and send the observing plan to the telescope

  1. Go to nadir computer and update TPG:
    cd ~/src/tpg/; git pull
    
  2. In the same directory generate the plan for a given night:

    poetry run tpg iris 2026/06/08
    
    The date is in format yyyy/mm/dd. Change it according to your current date. This command will create a plan in a directory /home/observer/src/tpg/plans/ with a name "iris_20260608_1.txt". This is the plan in TPG's format. The name of the file means that this is the 1st file generated for this night. Generate the file again and it will have the ending "_2.txt".

  3. Go to directory ~/src/iris/ and use python3 script "tpg2iris.py" to transform TPG format into IRIS format. The script accepts 2 arguments: name of input file and name of output file, but if you provide only one name, the program will overwrite the input file. Since plans for IRIS are stored in directory ~/TELESCOPES/IRIS/Plans/ let's use this location to save the plan in IRIS format:

    cd ~/src/iris/
    python3 tpg2iris.py ~/src/tpg/plans/iris_20260608_1.txt ~/TELESCOPES/IRIS/Plans/obs_plan_iris_20260608.txt
    

  4. In the same directory check the visibility of all targets in the plan (IRIS format) by running:

    python3 iris_planner_2026.py ~/TELESCOPES/IRIS/Plans/obs_plan_iris_20260608.txt [yyyy/mm/ddThh:mm:ss.s]
    
    If you add the argument of date & time (UT), the plot will be created starting this exact moment, otherwise it will start at a today's date when the Sun is at altitude -16°. The script shows more less the altitude of targets throughout the night (but needs some fine tuning), so if you see that any target goes below 40°, ignore it for now and pay attention to the observations in real time. Most targets come in 3 filters (JHK) or 2 filters (JK), and these blocks are separated from others with a blank line in the plan in IRIS format.

    The plan starts with a focus field (by the time the focus ends, the Sun is already at -18), and has a DARK exposure allocated in the middle of the night.

  5. In the same directory run another script to copy the plan to the "irisc" computer.

    bash cp_to_irisc.bash ~/TELESCOPES/IRIS/Plans/obs_plan_iris_20260608.txt
    
    The passowrd for "irisc" is on the cork board in the control room.

Prepare the software environment

  1. On aux computer open Remmina Remote Desktop Client (Fig. 9). From drop-down menu select "VNC" and to the right type:
    192.168.7.130
    
    to enter irisp machine (irisp, p from pilar), provide a password.
  2. On the irisp desktop software "Pilar" should be running (Fig. 10). If it's not, start it by clicking icon "4Π" (Four Pi) on the desktop. Pilar has tabs located on the bottom part of the screen: Telescope, Pointing, Ponting Model, Position, Auxiliary, Engineering. Click on "Engineering" and push "Clear errors" button if there are any errors to clean. Otherwise stay in the Telescope tab. The yellow status of "SYSTEM" (WARNING) and the red status of "Telescope status" (NOPOWER) are normal.
  3. Back on aux computer, in Remmina type:
    192.168.7.133:1
    
    and
    192.168.7.133:2
    
    to open two desktops on irisc machine (irisc, c from computer). Provide a password. If the two windows failed to open, see section Troubleshooting.
  4. In both windows several Xterms should be open; if not you can left-click the mouse and select "Xterm" to open a new terminal. You will need at least 6 terminals (e.g. 4 in the :1 desktop, and 2 in :2 desktop, see Fig. 11).

Remmina Remote Desktop Client
Fig. 9. The window of Remmina Remote Desktop Client.

Desktop of irisp machine with Pilar software running
Fig. 10. Desktop of irisp machine with Pilar software running.

The view of 2 vnc desktops of irisc machine with Xterms
Fig. 11. The view of 2 NVC desktops of irisc machine with Xterms.

Evening sequence

Start programs (Sun at +5°)

  1. In Xterm 1 on :1 type:

    iris_dome.py -open
    
    The dome should open. Other options are:

    • -slew <azimuth> to slew to some azimuth
    • -park to park the dome
    • -open to open the dome
    • -close to close the dome
  2. In "Pilar", switch "Telecope status" to ON. The mirror covers open, and the mount of the telescope is ready to operate. The yellow field of "Telescope status" (STOPPED, SLEWING) is normal.

  3. In Xterm 2 on :1 activate ACS (Alma Common Software) by typing:
    acsRunup
    
    Wait about 1 minute, and 6 new Xterm windows will appear in the upper left part of the screen, though minimized. They are ACS containers and they run different components of the telescope.
  4. Click on each of the containers and check if the last message is "Ready". If yes, you can minimize them by clicking the upper left corner (white filled circle) and proceed. If not, try:
    acsStop
    
    Wait about 1 min until the 6 containers are closed and try again:
    acsRunup
    
    If the containers don't close, type:
    killACS
    
    Then try again with:
    acsRunup
    
  5. Optional: In Xterm 3 on :1 type:
    startMntGui.py 
    
    Mount GUI will appear, you do not need to do anything.
  6. In the first Xterm of :2 type:
    ssh irisuser@irisccd
    
    and provide password. You will connect to irisccd machine, which runs the camera. Once you're connected, type:
    iriscom
    
    This starts software that directly communicates with the camera. You do not need to do anything, it just has to be open and running (it prints many messages per second).
  7. In the second Xterm of :2 type:

    irisCCDGUI
    
    This opens the "IRIS CCD User Interface". Next, click in the upper right corner: "Select camera" → "IRIS" → "Connect" → "Camera on". The status will change to "Connected". A DS9 window will appear, where you will see the latest image taken by the camera. At the same time, in "iriscom" Xterm status messages will be printed frequently (see Fig. 12).

    The view of vnc desktops of irisc with mount GUI and CCD GUI scripts running
    Fig. 12. The view of vnc desktops of irisc with mount GUI and CCD GUI scripts running.

Evening sky flats (Sun at -4°)

In Xterm 1 on :1 type:

cd cwest
./irisSkyFlats.py K 5 H 5 J 5
With this command you will obtain 5 sky flats in filter Ks, H, and J, in this order. The telescope will go to a predefined position for sky flats, the dome will move automatically (if not, you can move it in one of the Xterms). It will do test exposures until the median counts are below 40k and will continue as long as the counts number is above 26k or specified number of flats, in this case it is 5 per filter. You can abort by pressing ctrl+c.

Start observations, focus first (Sun at -16°)

In Xterm 1 on :1 (assuming you're in cwest directory already) type:

./irisPlan_dome.py obs_plan_iris_yyyymmdd.txt
The plan is located in cwest directory, because you copied it there earlier. The first thing in the plan is a focusing procedure. It takes about 20 minutes. Once the focusing procedure is finished, you can take a look at the fitted curve by typing:
display lastofcus.png
The plan continues without stopping after the focus.

For every IRIS frame, the camera will be read out 3 times to deal with the fact, that there is no shutter. The 3 readouts are stored in one fits file.

During the night

IRIS freezes on a target

If everything goes smoothly, IRIS will observe targets without any problems. However, every night there is a problem - IRIS freezes on a target, most probably trying to dither to a location with such precision that it takes forever, i.e. more than 20 min. If you see in DS9 that no new image was created for the last 20 min, stop the plan, park the telescope (we don't know why but it works) and restart the plan. You will have to edit the plan to remove targets that have already been observed. All of this is done in Xterm 1 on :1. Type:

ctrl+z
killPlan 
./irisPlan_dome.py obs_plan_iris_park_mount.txt
gedit obs_plan_iris_yyyymmdd.txt
./irisPlan_dome.py obs_plan_iris_yyyymmdd.txt
Alternatively to gedit, you can use vim.

If IRIS doesn't continue with a given target again, run the above block of commands again, but this time remove the problematic target from the plan altogether. If that doesn't solve the problem and IRIS is still stuck, restart ACS. In Xterm 1 on :2 type:

ctrl+z
acsStop    [wait for containers to close]
acsRunup
Now, try again executing the observing plan.

Resuming after longer inactivity due to bad weather

After longer inactivity some ACS containers might close unexpectedly, or Pilar, or camera. When resuming observations after a few hours of inactivity (we assume the observing plan is already killed), make sure that:

  • All 6 ACS containers are present. If not, in Xterm 1 on :1 type:
    ctrl+z
    acsStop     [wait for containers to close]
    acsRunup    [wait for containers to open]
    
  • The camera is working as before. If not, start the camera again. You won't have to restart iriscom.
  • Pilar is visible through VCN server. Sometimes the VNC server spontaneusly goes down with the essage "Unable to connect to VNC server". In such case just wait a few minutes and try to connect again. If Pilar reported any errors, erase them. If Pilar is not working, start it from scratch.

Morning sequence

Finish observations (Sun at -18°)

When the Sun is at about -18° and the observing plan has not ended yet, abort observations. In Xterm 1 on :1 type:

ctrl+z
killPlan

Morning sky flats (Sun at -7°)

Wait until the Sun is at about -7° and start sky flats (in the order: J, H, K). In Xterm 1 on :1 type:

./irisSkyFlats.py J 5 H 5 K 5

Close programs

  1. Close the IrisCCDGui: Disconnect → Camera off → Quit
  2. Exit from DS9
  3. Optional: exit from irisMntGui
  4. In Xterm 4 on :1 type:
    acsStop
    
    The containers will close in about a minute. If they don't close, type killACS
  5. In Pilar press "OFF" and wait until the mirror covers close (check on CCTV cameras).
  6. In Xterm 1 on :1 type:
    iris_dome.py -park
    iris_dome.py -close
    
  7. Check on the CCTV camera that IRIS is in its parked position and the dome is closed.

Renew the vacuum

The procedure takes 2 days in total, so better not lose vacuum in the first. place.

  1. Check the temperature of the camera - plug a thermometer to it [is this procedure still valid?] If the temerature if above 77K (by how many degrees?), the vacuum is lost and has to be renewed. Alternatively to the camera temperature you will see on the images taen by IRIS taht ... [will it be visible?]
  2. Check the pressure in the vacuum chamber - another way to check if renewing vacuum is needed.
  3. To renew the vacuum you must first warm up the camera to ambient temperature.
  4. Use the yellow handset (figure 2(d)) to turn the derotator by 180° towards the standard position. In this position you can connect the vacuum pump to the camera.
  5. Connect the vacuum pump (figure 2(e)) and the manometer (figure 2(f)), and start pumping with the camera valve closed (figure 3(a)).
  6. Once good vacuum [how much is it in bars? Where to check it?] is established in the pump and the hose, open the valve slowly and start pumping the camera.
  7. Once good vacuum [how much is it in bars? Where to check it?] is established in the camera, close the camera valve and start cooling with LN2.
  8. Keep pumping and after the cooling is finished open the valve again to pump to the final level at about 10−6 [unit?].

Troubleshooting

Contact person: Piotr Wielgórski
Email: pwielgor@camk.edu.pl, pwielgorski@gmail.com
WhatsApp: +48 518-385-197

Table of contents

IRIS knowledge

How old scripts works

IRIS setup

Syntax of IRIS plans

The prefix "type" chooses a predefined observation mode for the telescope: "flat", "focus", "seqquart". It is strongly recommended to use the predefined sequences, because they have been optimized to guarentee photometric results. The pipeline to reduce the images will also expect the predefined sequence format.

Type Exposure time Explanation
agn 1200 ???
seq 2200 standard sequence with standard sky
seqdouble 4400 same as seq with longer exp-time
hodapp 2200 predefined sequences with special sky postions near galactic plane
flat 1400 flats are taken at dark time in park position
focus 600 ???
seqquart 360 11 exposured dithered

How to use tests scripts