Maintenance of Telescopes and Instruments

Remote power switch and com ports

JK15 & ZB08

The remote power switch is located in a grey cabinet mounted to the pillar of the JK15 and on the wall in ZB08 on the ground floor. There are 8 com ports (communication ports) in total:

  • port 1: main drivers (responsible for movements of the telescope in Alt/Az axis)
  • port 2: aux (ancillary drivers: focuser, derotator, filter wheel, mirror covers)
  • ports 3-5: free
  • port 6: (only JK15) - sockets on the pillar upper floor, including iKon camera power supply.
  • port 7: dome (powers the grey box on the second floor in a direct vicinity of the telescope)
  • port 8: TCU computer

The com ports can be switched on/off manually from the remote power switch or via a website:

JK15 remote power switch
Fig. 1. JK15 remote power switch.

JK15 USB extenders

Note

There is a plan to discontinue the utilization of USB extenders in light of their unreliable performance. As of August 22, 2023, USB extenders are still in use.

2023-06-20 the iKon camera have been connected via Ikron USB 2.0 Ranger® 2304 USB extenders. Fig. 2 shows both sides of the extenders. Upper module (LEX) is in the pillar next to TCU computer.

The lower module (REX) is located outside of the telescope fork on the camera side.

The power supply is connected to the REX module, this is a possible point of the power cycle.

JK USB extender
Fig. 2. _Ikron USB 2.0 Ranger® 2304_ USB Extender. On a top LEX - TCU side unit, on a bottom REX -- Camera side unit.

Telescope balance

The telescope should be very slightly unbalanced to have a tendency to go to zenith rather than nadir.

In order to check the balance of the ASA telescope (JK15, ZB08, WK06), the following steps should be performed:

  • Run Autoslew
  • Motors On
  • Put altitude about 60deg
  • Menu Drive --> ServoSetup --> Balance

After the start, the telescope performs micro movements in a specified axis. In the horizontal mount, the RA axis is the AZ axis, and the DEC axis is the ALT axis.

The display shows averaged current of the motor separately for each direction. Differences in range 0.5A are OK (depending on the telescope). If the telescope is well-balanced, the current should be the same in both directions.

Manual check of the balance when the motors are off is also possible. Go to the dome and move the telescope a little bit out of balance. Where does the telescope go? Does it stay in its new place? If it stays where you put it, the balance works well.

Collimation

The collimation procedure is necessary after the installation of the telescope or after very strong earthquakes. You will know that the telescope desperately needs collimation because the stars will look like triangles and not circles (Fig. 3).

uncollimated-stars
Fig. 3. An image from ZB08, taken with an uncollimated mirror. Visible is the shape of the secondary mirror as well as triangular-like stars. This is the indication that the mirror is non collimated. In order to collimate the mirror in ZB08, put the collimation number in the home position (the home position has been defined by ASA and saved in the program).

The collimation procedure consists of a number of steps and requires patience and attention to details. Collimation ensures that the light travels parallel to the optical axis of the telescope. In order to do that you must observe light as it is emitted from the eyepiece behind the primary mirror, bounces from the secondary mirror and arrives to the eyepiece behind the primary mirror again. The general rule is the same for all telescopes although the details are slightly different. Below I present the routine that was executed for WK06. This procedure and procedures for other telescopes can be founds in the telescopes' manuals: WK06, ZB08, JK15.

Collimation tools are in the collimation box (Fig. 4). The tools are:

  • collimation laser (a red tube)
  • Takahashi Collimation Scope (a red disk)

collimation-kit
Fig. 4. Collimation kit. Every telescope has one kit like that, and they are identical. So in total we have 3 collimation kits. The empty area in the box in there by design, no tool is missing.

The crux of the collimation procedure is to turn the right screws the right way. There are 3 collimation screws at the primary mirror and 3 at the secondary mirror, 120 degrees apart. Every collimation screw is located inside a counter nut, which keeps the collimation screw fixed in place (Fig. 5). In order to move the collimation screw you first have to loosen the counter nut. After the collimation screw has been adjusted, tighten up the counter nut back.

collimation screws and nuts
Fig. 5. Counter nut (top) and collimation screw (bottom). Image courtesy of ASA. The full instruction is in the ASA manual for 0.6-m telescope, page 28.

Warning

Collimation is done without cameras, so you have to dismount them if you want to (re)do the collimation.

Primary mirror collimation for WK06

Insert the Takahashi Collimation Scope (a red disk) into the eyepiece. Don't screw it in any way! Just hold it in the eyepiece. The scope is a little bit loose – hold it so it won't fall off. The inside and outside spider struts should be in line (Fig. 6), but if they are not, adjust the 3 collimation screws. Each screw is responsible for "moving" the mirror in one direction, defined by the location of the screw. In order to move the screw, loosen the counter-nut first. If the screw still doesn't move, it is possible that it reached the end of the collimation range and can be only moved in the opposite direction. Always remember to tighten back the counter nuts, so that your effort is not lost!

collimation-primary-mirror
Fig. 6. Left: Basic check of the main mirror collimation. Do you see the inside and outside spider struts in line? Right: A collimation screw inside a counter nut. 3 screws+nuts like that are located every 120deg around the tubus of the primary mirror.

For fine-tuning of the primary mirror you must wait for the night time and put a bright and strongly defocused star in the center of the field of view. You should see the shadow of the secondary mirror on the disk of the defocused star. The shadow should be perfectly in the middle. If it is not, move the collimation screws until it is. This procedure is described in the ASA manual for 0.6-m telescope, page 31.

Warning

Tilting the mirror with collimation screws does not require much force. If you feel a resistance, you might have reached the end of the collimation range. In this case turn the current collimation screw a bit back and proceed with the collimation using the other 2 screws. Otherwise, you might apply stress to the optics.

Secondary mirror collimation for WK06

The collimation of the secondary mirror happens in two steps. It requires a collaboration of two people.

  1. Place a laser (a red tube) in the eyepiece. Turn on the laser, don't screw it to the eyepiece. You will see a faint red dot of the laser on the secondary mirror (M2). Your job is to place this dot exactly in the middle of the white triange on the M2 (Fig. 7, the right panel). You can do that by asking your partner to turn the 3 collimation screws of the M2 (Fig. 8). Each screw is responsible for "moving" the red dot in one direction (towards or away from the center of the triangle, depending on the direction of screwing). If the screw doesn't want to move, check if you loosened the counter nuts. If you have, but the screw still doesn't move, it is possible that it reached the end of the collimation range, and can be only moved in the opposite direction. Doing so will put the dot away from its destination, but remember that you still have 2 more collimation screws to adjust. Using them and your guidance (left, right, up, down), your partner will place the dot in the center of the triangle (Fig. 7). Always remember to tighten back the counter nuts, so that your effort is not lost!

    collimation-secondary-mirror
    Fig. 7. The collimation of the secondary mirror is done best by 2 people. One looks at the triangle and guides the other one that moves the collimation screws.

    collimation-secondary-mirror
    Fig. 8. A collimation screw inside a counter nut of the secondary mirror.

  2. Fine-tuning with Takahashi Collimation Scope (a red disk). Put the scope in the eyepiece, don't screw it, but hold it so it will not fall out. Look through the scope and notice a triangle with a black dot close to the middle. Your (and your partner's) job is again to put the dot perfectly in the middle by moving the collimation screws in the secondary mirror.

Collimation for ZB08

The collimation of ZB08's mirror(s) is done in the software ACC (red window). ASA set 3 collimation values (a digital varion of the collimation screws) to the values for which the collimation is the best. If the telescope de-collimates, set the collimation values to "Home position".

Tip

ZB08 sometimes tends to decollimate, and we don't know why. If this happens and the starts become triangular as in Fig. 1, set the collimation values in the software ACC (red window) back to home values. This procedure is explained in the text.

Otherwise, the collimation is very stable over years and decades of telescope usage. If the collimation is needed again, probably more things require acquisition too. At this point it's worth considering inviting ASA specialists to OCM again, so they can handle it.

Collimation for JK15

The same as for ZB08.

Pointing model

The proper pointing model is necessary for telescopes to correctly calculate where they point. The pointing model can become obsolite for a number of reasons:

  • eartquake,
  • rebalancing the telescope,
  • small drifts that accumulate with time.

You can check the accuracy of pointing on every image displayed at OCM: a circle points to a star, a cross point to the pointing coordinates in the middle of the field, which should coincides with the target star. Ideally these two figures (circle and cross) should overlap – that means the pointing model is perfect. Only in a few situations the cross and circle will not overlap, when the star marked with a circle is intentionally moved away from the center of the field. This can happen because:

  • on JK15 a target is put in one specific chip of the CCD instead of in the middle where 4 chips meet,
  • a very bright star is in the FoV and produces undesired illumination (e.g. spikes of light).

In any other situation if the circle and cross are far away (more than a half of the size of the FoV), you should report this to oca-operations, and – with their blessing – perform the pointing model.

"Sequence" program for pointing model

Pointing model is a done with a program "Sequence", installed on all telescopes' computers. In order to create a new pointing model, follow the instructions:

Other materials you might (or not) find helpful:

  • https://www.youtube.com/watch?v=tVvXna7Sw00
  • https://youtu.be/F8oiGlttWb0?t=689&si=a99-G2zdty5WkvEa
  • https://www.youtube.com/watch?v=yoe-25-l77o
  • https://www.youtube.com/watch?v=1mrjV1gOUk0

Once you successfully perform the pointing model, report it to oca-operations.

(De)Rotators

Normally, rotators are controlled by AutoSlew, and do not require any manual intervention.

rotator-setup
Fig. 9. Rotator setup in AutoSlew.

But there are issues that may require some changes. Known issues are listed below:

rotated-fits
Fig. 10. Rotated FITS image.

TCU Computers preparation

The TCU computers are Windows computers mounted on the ASA telescopes.

For our purpose, those computers need some preparation. The tasks below, are performed on the new TCU computers, and there is no need to repeat them once the computer is set up.

De-germanize the keyboard

TCU computers provided by ASA have some German localization settings, including German keyboard layout. In order to install the English keyboard layout, the following steps should be performed:

To change your keyboard layout in Windows 10 from German to your desired layout, follow these steps2:

  1. Click the Windows icon in the lower-left corner of the screen to open the Start menu.
  2. Type "Settings" in the search bar and click on the Settings app (it has a gear-shaped icon) to open it.
  3. In the Settings window, click on "Time & language."
  4. In the Time & language menu, click on "Language" in the left-hand pane.
  5. Under the "Preferred languages" section, you should see a list of installed languages. If your desired language is not listed, click on "Add a language" and search for it in the search box. Select the language and click "Next," then follow the on-screen instructions to install it. If your desired language is already listed, skip to step 6.
  6. Click on your desired language and then click the "Options" button.
  7. In the "Keyboards" section, you will see the currently installed keyboard layouts. Click on "Add a keyboard" and select your desired keyboard layout from the list (US QWERTY).

Now you can change the active keyboard layout from the taskbar. Leave the German layout for ASA maintainers.

Enabling Remote Desktop

  • Right-click on Windows icon in the bottom left corner ans select System
  • Click Remote Desktop on the left side
  • Turn on Enable Remote Desktop
  • Click Advanced settings
  • Deselect Require computers to use Network Level Authentication to connect (recommended)3
  • Try to connect using rdesktop:
    rdesktop -u asaroot -p - zb08-tcu.oca.lan
    
    (change the hostname accordingly from zb08 to jk15 or wk06)

If you are able to connect, the remote desktop is enabled.

Enabling DWService

The DWService is a remote access software, which allows connecting to the computer without the need of VPN connection. The control is done via a web browser. See DWService for more details.

  • Add the computer agent to the DWService account, adding it to the group OCA-admins.
  • Notice the agent installation code (e.g. 261-007-974).
  • Download DWService agent installer from DWService on the TCU computer.
  • Run the installer and choose to install an agent.
  • Chose to configure the agent by entering the installation code.
  • Enter the code from the previous step.

Make it pingable

The TCU computers are not pingable by default. To make them pingable, the following steps should be performed:

  • Open Windows Security
  • Click Firewall and network protection
  • Click Advanced settings
  • On the Windows Defender Firewall with Advanced Security window, click Inbound Rules
  • Find the rules File and Printer Sharing (Echo Request - ICMPv4-In)
  • Enable all these rules by clicking on them and selecting Enable rule

Check if the computer is pingable from the OCA network.

Domes maintenance

Cleaning the domes

If you know how, share this knowledge by contributing to this manual.

Oiling the domes

When opening/closing the domes, check for the level of noise via the CCTV cameras or in person by standing next to the dome as the other observer opens it. Is the sound of the dome shutter opening above the regular noise? If yes, the shutter might need oiling. How to oil the dome shutter? It hasn't been revealed yet, but Rolf Chini or Grzesiek Pietrzynski might know. Ask them and consider to share this knowledge by contributing to this manual.

Mirror maintenance

Mirror quality control

From time to time you will see in the OCM calendar a task mirror quality control or mirror quality check. This means that you should take photos of the primary mirrors of WK06, ZB08, and JK15 telescopes. This visual check is to asess how much they deteriorated over time, and how much dust has accumulated.

Taking a picture of a mirror is tricky because they reflect everything, so in order to take a proper photo:

  • take two headlights from the control room,
  • lower the telescopes to altitude 15 deg using TOI,
  • open the mirror covers from TOI,
  • put both headlights inside the telescope as close to the mirror as possible without the touching the mirror. Point the light towards the center of the mirror so that the light rays go almost parallel to the surface of the mirror, they almost "graze" the surface of the mirror (Fig. 11),
  • take (a) photo(s).

Upload the photos to Google Drive's OCA/Tests of telescopes and instruments/Mirror quality control/. Preserve the catalog tree. Next, link the "Mirror quality control" directory to OCM calendar, as done previously.

mirror quality control
Fig. 11. Exemplary photo of the mirror quality control.

Mirror cleaning

The mirror(s) should be deep-cleaned with a sponge once a year. It is a delicate procedure and only Rolf Chini is "certified" to do this. Here are the images and footages of this procedure. Pay attention to the protective cloths: gloves, a hat, and a mask, that are necessary to ensure that the mirror won't get contaminated during the cleaning. A cleaned mirror collects up to 30% more light (0.3 mag).

The procedure of the cleaning the mirrors consists of the following steps:

  1. Find a partner to clean the mirrors with. It's easier and faster when someone assists you, e.g rinses the sponge (more about that later).
  2. Prepare protecting clothes for yourself: a hat, a mask, and a few pairs of gloves (at least 3 pairs).
  3. Prepare 3 containers: 1) with only detergent, 2) with distilled water, and 3) empty container for the dirty water when you rinse the sponge. Prepare 2 big sponges (one for cleaning with detergent, the other for cleaning with water).
  4. Point the telescope to the altitude of 15 deg. Change its azimuth if needed. Open the mirror covers.
  5. Take the 3 containers, 2 sponges, and a big container with distilled water with you to the telescope.
  6. Open slightly the dome to let the natural light in. You might need to move the dome or telescope to shield the telescope from strong wind (if there is any).
  7. Person A walks "inside" the telescope rods ("Mission Impossible") while person B takes a big sponge and soaks it in the detergent in the container 1. Rinses it a little and gives it to person A.
  8. Person A dabs the sponge on the surface of the primary mirror. Don't smudge! That would create micro-scratches.
  9. Once the mirror is wet with the detergent, the clock starts ticking. The detergent has to be removed from the mirror before the water from the detergent evaporates and the detergent dries on the mirror. Person A gives the sponge back to person B. Person B puts the sponge in the container with the detergent and takes the other sponge from the container with distilled water. Rinses it a little and gives it to person A.
  10. Person A takes the clean sponge and dabs again on the primary mirror. The dabs take the detergent with the sponge. Person A gives the now-dirty sponge to person B.
  11. Person B, standing above the container 3, pours water on the now-dirty sponge and rinses it from the collected detergent. The dirty water lands in container 3. Repeat this 3 times. On the fourth time, pour some water on the sponge and don't rinse it completely. Give the sponge to person A and the process from points 10-11 repeats until the mirror is detergent-free, at least 3 times.
  12. Repeat the cleaning procedure for the tertiary mirror of needed.
  13. After cleaning person B receives the sponge for the last time from person A, rinses it above container 3, and puts in container 2, where it initially was. Meanwhile person A gets out of the telescope.
  14. Close the dome shutter, return to the main building, close the mirror covers and park the telescope.
  15. Put in the calendar and report immediately to oca-operations which mirrors have been cleaned. This marks a new era for sky flats.

Primary mirrors of ZB08 and WK06 can be dabbed in "one go" while JK15's primary mirror has to be divided into 4 areas and cleaned one area at a time. Cleaning the JK15 mirror requires climbing on a ladder for person A.

After the cleaning is complete:

  1. Clean with distilled water and rinse both sponges separately.
  2. Clean containers 1, 2, and put all the dirty water to container 3. Use that water to water the electric grounding.
  3. Put sponges in their respective containers: sponge used with detergent in the container 1, sponge with distilled water in container 2.
  4. Keep the containers 1 and 2 open for 24h to let them dry. After that flip the sponges and let them dry for another 24h. Set an alarm clock/reminder is necessary.
  5. After 48h close the lids of containers 1 and 2, and store them in bodega on RACK 5.
  6. Check after a few days if some remaining water hasn't condensed on the walls and lids of the containers. If yes, open them and dry, executing steps 4-5.

Update Observatory Configuration after Mirror Cleaning

After the mirror cleaning, configuration of the observatory has to be updated before shooting any images.

Ask IT Staff - Mikołaj, Mirek or Marek - to update the configuration.

Neglecting configuration update will cause inconsistencies in FITS instrumental calibration process.

Background Information

The FITS files have header fields FLAT_ERA, ZERO_ERA, and DARK_ERA, which describe the era of the calibration files used for the image instrumental calibration. The value to be written to these fields is taken from the configuration of the observatory, published in NATS. Cleaning the mirror changes the sensitivity of the telescope+camera system and the distortion pattern, so new FLATS must be taken and used for the instrumental calibration. During the calibration process, the calibration files with the same era as in the science image are used, based on proper values in the FITS headers. You can learn more about the observatory configuration in the Observatory Configuration section of this manual.

Camera cleaning

The cameras should be cleaned every year. Unfortunately, we don't have a procedure to do it yet. Can you help? Do you know a procedure? Please, consider contributing to this manual.

Assembly of filter wheels

WK06

Before disassembling the camera and filter wheels, mark the exact position and angle of the camera and filter wheels with respect to the telescope, so that when you assemble it back, it will be in the same position as before. Before the disassembly, the telescope and its filter wheels should look like in Fig. 12.

wk06 assembled
Fig. 12. WK06 telescope and its filter wheels before disassembly.

Write in the OCM calendar when the disassembling took place, and let oca-operations know as well.

When assembling back, write it in the OCM calendar and write to oca-tech [at] camk.edu.pl, so that they can update the configuration of the observatory ("era"). If you don't do that, we will be using outdated calibration images and producing wring science data.

The following instruction was written by bzgrski. If in doubt, contact him.

  1. When the filter wheels are disassembled/assembled, the telescope must be blocked manually. To block the telescope's axes, push the 2 pins in (Fig. 13). When the telescope is blocked manually, the mount motor will have no effect when it's turned on. Keep the mount motor turned off as long as the telescope is manually blocked.

    wk06 blocking pins
    Fig. 13. Blocking pins located on the WK06 mount.

  2. Use a table and lift to support the camera during the disassembly. Disconnect cables from the camera and filter wheel. One observer looses the screws marked on Fig. 14, the other one holds the camera. Slowly lower the lift with the camera. Remember to mark with the tape the orientation of the parts before you dismount them.

    wk06 disassembling
    Fig. 14. Marked are the screws that need to be loosened to disassemble the camera and filter wheels.

  3. There are two filter wheels. The "lower" filter wheel is attached to the camera and used to have empty spaces (Fig. 15) now filled with the Sloan filters. The "upper" filter wheel has a full set of filters and one empty space under number 10.

    wk06 filter wheel
    Fig. 15. The "lower" filter wheel of WK06. This one is attached to the camera and has spaces for the Sloan filters.

    Proceeding with the assembly, close the "lower" wheel with a top cover using 5 screws (marked in red in Fig. 16). Screws marked in green have to be taken out at this stage, as they will attach this "lower" filter wheel to the "upper" wheel later. The screws enter the "lower" wheel in the same place as in the image, but they first go through the lower cover of the "upper" wheel.

    wk06 filter wheel
    Fig. 16. The cover of the "lower" wheel of WK06 with the location of screws.

  4. Before you attach "upper" and "lower" filter wheels together, connect the cable between them – later it is impossible (Fig. 17).

    wk06 disassembling
    Fig. 17. A cable that must connect the "upper" and "lower" filter wheels before they can be assembled.

  5. To attach the two filter wheels together (one on top of the other) the"upper" wheel (full set of filters and one empty space under number 10) needs to be opened using the analogical 5 screws. In this "upper" wheel you need to unscrew the turntable (a screw marked with purple, Fig. 18) and lift it to have access to all 4 connections of the two filter wheels. Green markings show the same screws as in Fig. 16. Attach the two filter wheels together, put back the turntable, and screw it back (not too tight because you will tighten it more in step 7).

    wk06 filter wheel
    Fig. 18. Location of screws in the "upper" wheel of WK06.

  6. Put back the belt and connect the turntable to the motor. The black belt is visible in Fig. 19, but detached. You have to put it on the motor after attaching the two filter wheels together.

    wk06 filter wheel
    Fig. 19. The "upper" wheel with its belt. The belt is detached on this photo.

  7. Close the "upper" filter wheel and attach it to a connector (Fig. 20). Align these elements in such a way that paper tapes on their sides are aligned in one line. Tighten all the screws.

    wk06 filter wheel
    Fig. 20. The connector.

  8. Attach the upper connector to the telescope, and connect 3 cables visible in Fig. 21. The USB-C cable goes to the red guiding camera, and the other 2 cables enter the camera in the sockets presented in Fig. 22.

    wk06 cables
    Fig. 21. Cables.

    wk06 camera sockets
    Fig. 22. Sockets.

  9. Connect the cable from Fig. 23 to the "lower" filter wheel. The "lower" wheel has a cable with a flat plug (Fig. 24) that connects it to the "upper" filter wheel (socket on the lower cover in Fig. 25).

    wk06 cable
    Fig. 23. Cable

    A flat plug of the lower wheel
    Fig. 24. A flat plug of the "lower" wheel.

    A socket on the lower cover of the upper wheel
    Fig. 25. A socket on the lower cover of the "upper" wheel.

  10. Put the camera with filter wheels onto lift on a table and connect to the telescope (Fig. 26).

    wk06 filter wheel assembly
    Fig. 26. A socket on the lower cover of the "upper" wheel.

  11. Unblock the telescope by pulling the 2 pins out (Fig. 13). Only now you can turn on the mount motor.


  1. 2023-05-08 ↩